en:user:problem:heat:linear
Solver control parameters for steady-state linear analysis
The control parameters of the XT2S/XT3S solver are specified in the name.iB file:
IP 1 0 2 0 0 1 1 RP 5*0 PIVOT PENAL
$\mathtt{PIVOT}$ is the minimum allowed pivot value during matrix factorization. The default value is $10^{-6}$.
$\mathtt{PENAL}$ is the penalty function value for connector elements of all types. The default value is $10^6$.
The assignment /R TIMX STEP TSC/ in the AS batch and the AV set are not used.
Each load case corresponds to a single record containing a steady-state temperature field in both the name.TEM and name.STR files.