************************************************************************ * * * test example * * * * parameters description * * * * NB MODEL identification of the Norton-Bailey model * * PMD/ANSYS flag specifying which coefficients are present * * T K N M - PMD * * T C1 C2 C3 - ANSYS * * POCET DAT the number of data lines (max. 30) * * DATA 4 parameters on each line * * T temperature in deg. Celsius * * K model parameter * * N model parameter * * M model parameter * * * ************************************************************************ NB MODEL PMD POCET DAT 5 DATA 570 3.02676E-13 4.3128 0.3633 580 6.2959E-14 4.5927 0.4204 590 9.45498E-15 4.9251 0.4922 600 7.00039E-16 5.3745 0.5907 610 2.168E-17 5.9644 0.7260